The Sysmon OnlinePRO (SOP) is a platform-independent system monitoring unit designed to monitor and control internal parameters of a system platform, such as voltages, temperatures, digital inputs, and fan speeds. It utilizes a 16-bit microcontroller with an integrated 12-bit A/D converter to analyze these parameters at regular intervals. If a parameter exceeds or falls below user-defined limits, the unit detects this as an event and can trigger pre-defined actions or set digital outputs.

What's inside

  • Product description and functions
  • Voltage monitoring
  • Temperature monitoring
  • Fan monitoring and control
  • Digital inputs and outputs
  • Generating ACFAIL and SYSRESET VME signals
  • Ethernet interface
  • RS232 serial interface
  • WEB interface
  • Command Line Interface (CLI)

Specifications

Microcontroller16-bit microcontroller
A/D Converter12-bit integrated
Voltage Monitoring InputsUp to 8 voltages
Temperature Sensors (Analog)Up to 6 analog sensors
Temperature Range-20°C to +100°C
Temperature Accuracy+/-3°C (max.)
Fan MonitoringUp to 12 fans
Fan PWM Frequency20Hz to 10KHz
Digital I/O Ports16 inputs, 16 outputs
Logic Level5V TTL

Frequently asked questions

What is the temperature measurement accuracy of the Sysmon OnlinePRO?

The temperature measurement accuracy is +/-3°C maximum.

Can the fan speed be controlled via PWM?

Yes, fan speed control is possible via a PWM signal with a configurable frequency from 20Hz to 10KHz.

How many analog temperature sensors can be monitored?

The unit can monitor up to 6 analog temperature sensors.

What logic level is used for the digital inputs and outputs?

The logic level for the digital inputs and outputs is 5V TTL.