This manual provides installation, commissioning and maintenance instructions for the SAGE RIO Models SIX and SRX thermal gas mass flow meters.
This manual provides instructions for the Sage Metering RIO Models SIX and SRX, a family of high-performance thermal gas mass flow meters certified for hazardous service. The devices feature a dual-compartment windowed enclosure with a photo-emissive OLED display and are designed to measure mass flow directly without ancillary instrumentation.
| Power Dissipation | under 2.5 watts |
|---|---|
| Power Supply | 24 VDC (12 VDC optional, or 115/230 VAC) |
| Turndown Ratio | up to 100 to 1 |
| Resolution | 1000 to 1 |
| Sensor Material | Platinum windings |
The meters can measure the mass flow rate and consumption of air, oxygen, natural gas, nitrogen, digester gas, biogas, flare gas, hydrogen, argon, carbon dioxide and other gases and gas mixes.
No, the meters measure mass flow directly and do not require ancillary instrumentation such as temperature or pressure transmitters.
Yes, the manual states that the RIO Models SIX and SRX are certified for hazardous service.