This document is the operations and instruction manual for SAGE THERMAL GAS MASS FLOW METER, specifically for the SAGE RIO models SIX and SRX. It provides information on the features and characteristics of the products.
The document serves as an operations and instruction manual for the Sage Metering RIO Models SIX (Integral Style) and SRX (Remote Style). It provides detailed guidance on unpacking, installation in hazardous locations, wiring configurations for both integral and remote styles, and maintenance procedures. The meters are designed to measure mass flow directly without ancillary instrumentation.
| Power Dissipation | under 2.5 watts |
|---|---|
| Turndown Ratio | 100 to 1 |
| Resolution | 1000 to 1 |
| Upstream Straight Run | minimum of 15 pipe diameters |
| Downstream Straight Run | 5 diameters |
They can measure air, oxygen, natural gas, nitrogen, digester gas, biogas, flare gas, hydrogen, argon, carbon dioxide and other gases and gas mixes.
The meter has a turndown capability of up to 100 to 1.
It is recommended to have a minimum of 15 pipe diameters of straight run upstream.