This document introduces the installation and maintenance instructions for NEMA 449T Frame SGM Type three-phase induction motors
This instruction manual covers the installation, connecting-up, and starting procedures for Elektrim NEMA 449T Frame SGM Type three-phase, squirrel-cage, horizontal, foot-mounted induction motors. The document details technical descriptions, design specifications, and permissible service conditions including ambient temperature and altitude adjustments.
| Motor Type | Three-phase, induction, squirrel-cage, horizontal, foot-mounted |
|---|---|
| Frame Number | 449T |
| Insulation Class | F |
| Ambient Temperature Range | -20°C to +40°C |
| Maximum Altitude | 3300 ft (approx. 1000m) |
| Minimum Insulation Resistance | 50 MΩ |
Permissible variations in supply voltage are ±10% of rated voltage at rated frequency, and permissible variations in supply frequency are ±5% of rated frequency at rated voltage.
The insulation resistance reading must not be less than 50 MΩ when measured between lines and between each line and frame using a 500V megger.
No, the motors must not be operated in hazardous locations where flammable vapours or gases are present, or where combustible or electrically conductive dusts are present.