This manual contains technical information for the NSM-3E series signal monitor unit. The monitors are designed and manufactured in the USA by Eberle Design Inc. Information contained herein is proprietary technical information of Eberle Design Inc. Publication, reproduction or use in whole or in part is not permitted except under terms agreed upon in writing.
The NSM-3E Series Signal Monitor is a device used in traffic controller assemblies to monitor traffic signals at an intersection for conflicting proceed indications or the absence of voltage on all field signal outputs. It meets or exceeds NEMA TS-1 specifications and is directly interchangeable with a standard NEMA 3-channel Signal Monitor.
The manual details the monitor's standard functions, including conflict monitoring, red failure monitoring, and voltage monitoring for +24VDC supplies and controller outputs. It also covers extended features such as dual indication monitoring, clearance monitoring, and LEDguard sensing, along with installation instructions and front panel descriptions.
| Channels | 3 channel |
|---|---|
| Monitored Signals | Green, Yellow, Red, Walk |
| Red Failure Timeout | 1000 msec |
| Red Failure Ignore Time | 700 msec |
| AC+ Brown-out Threshold | 475 msec |
| AC+ Restore Threshold | 100 msec |
| Power Requirements | AC+ |
The monitor enters the fault mode, de-energizes the Output relay contacts to the Fault position, and illuminates the CONFLICT indicator.
Red Failure Monitoring is disabled when the Red Enable input is not active.
No, the loss of AC+ power will not reset the fault mode of the Output relay contacts.
This function is enabled by the front panel option switch labeled "WALK DISABLE".