This manual includes the operating instructions for the CLe-series dishwashers.
This manual provides detailed instructions for installing, operating, and maintaining Hobart CLe and CLeR-Series dishwashers. It covers plumbing, electrical, and chemical feeder connections, as well as programming and troubleshooting. The CLeR models include an energy recovery system for preheating water. Safety precautions are emphasized, including gas safety and proper water treatment. The manual also details optional configurations like side loaders and corner scrapers.
| Energy Recovery System | Included in CLeR models |
|---|---|
| Booster Heater | 30kW, standard on CLeR models |
| Water Hardness | 3 grains per gallon or less |
| Chlorides | Not to exceed 30 parts per million |
| Water Pressure | 15 to 25 psig |
CLeR models include an energy recovery system to preheat water and come standard with a 30kW booster heater. CLe models do not have this system.
Incoming water and final rinse water must be at least 120°F, with tank heaters raising it to 130°F for wash.
The water pressure must be maintained at 15 to 25 psig.
Installation must comply with state and local codes or ANSI Z223.1 and ANSI/ NFPA 70 (latest editions). In Canada, use CAN/CSA B149.1 and CSA C22.1.