This document provides an installation, operation, maintenance and safety manual for low voltage motors. The content is detailed, including installation manual, operation manual, maintenance manual and safety manual.
This manual provides instructions for the safe and proper installation, operation, and maintenance of ABB low voltage motors. It covers handling procedures, installation requirements including foundation preparation and alignment, and electrical connection details. The document applies to various motor series including MT, MXMA, M2A through M3V in frame sizes 56 to 450.
| Applicable frame sizes | 56 - 450 |
|---|---|
| Insulation resistance reference value | 100 MΩ |
| Oven drying temperature | 90°C for 12-16 hours followed by 105°C for 6-8 hours |
The end user has full responsibility for preparation of the foundation.
The insulation resistance, corrected to 25°C, must exceed 100 MΩ.
The windings must be dried at 90°C for 12-16 hours followed by 105°C for 6-8 hours.
The height difference shall not exceed ± 0.1mm.