This manual provides detailed information on the installation, use, and maintenance of the HWS1000/ME power module.
This installation guide covers safety, servicing, environmental, and disposal instructions for the TDK-Lambda HWS1 000/ME component power supply. It is designed for integration into host equipment and must not be operated as a standalone product. Only authorized personnel may service or repair the unit. The product is IPX0 and must be installed in a Pollution Degree 2, overvoltage category II environment. End-of-life disposal requires compliance with local regulations.
| Product Type | Component power supply |
|---|---|
| Environmental Rating | IPX0 |
| Pollution Degree | 2 |
| Material Group | IIIb |
| EMC Directive | Not applicable |
No, this product is designed for use within a host equipment and must not be operated as a stand alone product.
Only TDK-Lambda UK LTD and their authorised agents are permitted to carry out repairs.
The product is IPX0 and must not be exposed to chemicals, solvents, cleaning agents or other liquids.
The output power must not exceed the rating stated on the power supply label, except as stated in the product limitations in this handbook.