This file is the DDA Installation Manual, which introduces the product's use instructions, safety information and installation instructions
This document serves as an installation manual for TDK-Lambda DDA component power supplies. It outlines critical safety instructions, including warnings about high voltage, the requirement for professional installation within host equipment, and restrictions on servicing by end users. The manual specifies that these units are not intended for standalone operation or sale to end users but are components for business-to-business distribution.
| Pollution Degree | 2 |
|---|---|
| Overvoltage Category | II |
| PCB Material Group | IIIb |
| IP Rating | IPX0 |
No, these products are not customer serviceable and must be repaired by TDK-Lambda UK LTD or their authorized agents.
No, it is not authorized for use in hazardous environments without express written approval from the Managing Director of TDK-Lambda EMEA.