This manual provides detailed information on the connection methods and circuit principles for the CC15-24xxSxx-E and CC30-24xxSxx-E series.
This document serves as an instruction manual for the TDK-Lambda CC15-24xxSxx-E and CC30-24xxSxx-E series of DC/DC converters. It details the standard connection methods, including input/output line connections and the use of external components like fuses and capacitors to ensure stable operation. The guide also explains how to utilize specific terminals for remote control, alarm monitoring, and simultaneous start-up/stop functions.
| Recommended Fuse Capacity (CC15) | 2A |
|---|---|
| Recommended Fuse Capacity (CC30) | 4A |
| Recommended External Capacitor Cin (CC15) | 33 uF |
| Recommended External Capacitor Cin (CC30) | 68 uF |
| Maximum Series Operation Units | 2 |
| Maximum Alarm Terminal Units | 20 units |
| Maximum PO Terminal Units | 20 units |
| Solder Dip Condition | 260°C 10 sec Max. |
| Solder Iron Condition | 380°C 3 sec Max. |
The recommended fuse capacity is 2A.
The maximum number of converters which can be operated in series is 2.
Yes, converters having different output voltages can be connected, but this applies only to converters belonging to this series.
The ALM terminal should be used at a maximum sink current of 10mA.