This document is a product manual that introduces the product types, models, specifications, etc. of the In-Sight Micro series vision system.
This manual provides step-by-step instructions for installing and configuring Cognex In-Sight Micro Series vision systems. It covers mounting, lens attachment, I/O connections, and Ethernet/PoE power setup. Safety precautions are emphasized, including proper voltage use and environmental conditions. The document also details regulatory compliance and model-specific specifications for various In-Sight Micro models.
The manual includes diagrams for cable connections, warnings about laser exposure and ESD, and guidance for connecting optional I/O modules. It references additional documentation for advanced configurations and lists compliance standards such as EN 55022 and FCC Class A. Spanish specifications are included for certain models.
| Operating Temperature | 0°C to 45°C (32°F to 113°F) |
|---|---|
| Storage Temperature | -30°C to 80°C (-22°F to 176°F) |
| Humidity | 90%, non-condensing (in service and storage) |
| Protection Rating | IP51 with cables and lens attached |
| Shock Resistance | 80 G with 50g or less lens, per IEC 68-2-27 EA |
| Vibration Resistance | 10 G, 2 hours per axis (10-500 Hz), per IEC 68-2-6 |
The manual covers In-Sight Micro 1020/1050/1100/1110/1400/1410, 1100C/1400C, 1402/1412, 1403/1413, 1403C, and 1500 models.
The system has an IP51 rating when cables and lens are attached.