This manual describes the water flow transmitter type 8081, including product description, technical data, installation and wiring instructions.
This manual provides detailed operating instructions for the Bürkert Type 8081 water flow transmitter, including safety precautions, installation procedures, electrical wiring, commissioning, adjustment, and maintenance. It covers technical specifications, fluid compatibility, and environmental conditions for proper operation. The device uses ultrasonic transit time measurement to determine flow rates and can output either pulse or current signals depending on the model variant.
| Protection Rating | IP65 |
|---|---|
| Fluid Temperature | +5...+90 °C |
| Fluid Pressure | PN 16 |
| Measuring Range | 0.06...200 l/min |
The Type 8081 can have a pulse output or a combination of pulse and 4-20 mA current output, depending on the model variant.
The housing is made of PPS, the seal in contact with the environment is silicone, the M12 connector is PA, the fitting is brass, and the measuring tube is PES with EPDM or FKM seals in contact with the fluid.