Weihong NK280 Integrated CNC System Manufacturer's Manual

The NK280 integrated CNC system manual introduces the system hardware configuration, installation size, connection diagram and software interface. It also introduces the hardware signal type, port wiring and interface definition content, and the operation and maintenance, alarm information and common fault handling of the operating system.


Weihong NK280 Integrated CNC System Manufacturer's Manual - cover page
Brand
WEIHONG
Document type
User Manual
Language
Chinese
Pages
185
File format
PDF
File size
4.2 MB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
E4FBEA3EFAD85D011D7169A59C0215EA

About this manual

The Weihong NK280 Integrated CNC System is designed for machine tool manufacturers and end users. This manual provides comprehensive instructions on hardware configuration, electrical cabinet inspection, installation, connection diagrams, and software interface usage. It details specific operational procedures for the general system as well as specialized configurations for drilling, milling, and grinding machines. This manual is written in Chinese.

What's inside

  • Introduction
  • Hardware Configuration
  • Signal Types and Connections
  • Parameter Settings
  • General System Operations
  • Drilling Machine Specifics
  • Milling Machine Specifics
  • Grinding Machine Specifics
  • System Messages and Faults
  • Parameter List

Frequently asked questions

What is the minimum wait time required after a power outage before restarting the system?

You must wait at least 1 minute before restarting the system after a power cut.

What is the maximum resistance allowed for the system's grounding wire?

The grounding wire resistance must be no more than 4 ohms.

How much clearance space must be left between the back of the control unit and the wall?

You must leave 100mm of space between the back of the control unit and the wall.