This manual will make you familiar with the installation and operation of our magnetostrictive sensors. Please read this manual carefully before initial operation!
The document serves as an installation guide for the WayCon MAP Series of magnetostrictive transducers. It outlines initial steps such as unpacking and checking for damage, along with important general notes regarding magnetic field interference and cable separation requirements to ensure proper operation.
Detailed sections cover the mounting of brackets using specific kits (PKIT590/PKIT591) and provide instructions on electrical connections for both M12 and EN175301-803 Form A connectors. It also lists compatible magnetic cursors and specifies power supply requirements.
| Power Supply | 24 VDC, ±20 % |
|---|---|
| Connector Type (MAP-A-A) | M12, 5 pins, male |
| Cable Length Limit | less than 30 mt |
The sensors must be powered with non-distributed networks and always at lengths of less than 30 meters.
The support must be made of non-magnetic material to avoid interference with the magnetic cursor.