WayCon MAP Series Magnetostrictive Sensor Installation Guide

This manual will make you familiar with the installation and operation of our magnetostrictive sensors. Please read this manual carefully before initial operation!


WayCon MAP Series Magnetostrictive Sensor Installation Guide - cover page
Brand
Waycon
Document type
Installation Guide
Language
English
Pages
4
File format
PDF
File size
307 KB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
22B4AB8EF3C1BFDB0FB92DF36CD91640

About this manual

The document serves as an installation guide for the WayCon MAP Series of magnetostrictive transducers. It outlines initial steps such as unpacking and checking for damage, along with important general notes regarding magnetic field interference and cable separation requirements to ensure proper operation.

Detailed sections cover the mounting of brackets using specific kits (PKIT590/PKIT591) and provide instructions on electrical connections for both M12 and EN175301-803 Form A connectors. It also lists compatible magnetic cursors and specifies power supply requirements.

What's inside

  • First Steps
  • General Notes
  • Magnetic Cursors
  • Mounting the Sensor
  • Electrical Connection

Specifications

Power Supply24 VDC, ±20 %
Connector Type (MAP-A-A)M12, 5 pins, male
Cable Length Limitless than 30 mt

Frequently asked questions

What is the maximum length for the sensor cable?

The sensors must be powered with non-distributed networks and always at lengths of less than 30 meters.

What material should the support for a floating cursor be made of?

The support must be made of non-magnetic material to avoid interference with the magnetic cursor.