This manual introduces the operation methods of Trimble SPSx30 total station.
This document is the Version 1 User Guide for the Trimble SPSx30 Total Station, published in June 2011. It provides instructions for the safe use and operation of the instrument, including specific warnings regarding laser radiation and battery handling.
The guide details the laser safety classifications for the instrument's various sources, including the distance measuring function (Class 1), the laser pointer (Class 2), and the tracker technology (Class 1). It also outlines safety requirements for the rechargeable Lithium-ion battery and lists compatible targets such as the Trimble MT900 and MT1000 MultiTrack Target.
| Laser Wavelength (Distance Measuring) | 905 nm |
|---|---|
| Laser Output Power (Distance Measuring) | <1.1 mW |
| Laser Wavelength (Pointer) | 630 - 680 nm |
| Laser Output Power (Pointer) | <0.7 mW |
| Laser Wavelength (Tracker) | 785 nm |
| Laser Output Power (Tracker) | <0.35 mW |
| Antenna Impedance | 50 ohms |
The Trimble SPSx30 DR Plus is a CLASS 2 LASER PRODUCT.
The visible laser pointer has a maximum output power of less than 0.7 mW.
The antenna must be installed to provide a separation distance of at least 20 cm from all persons.
The required antenna impedance is 50 ohms.