This manual introduces the technical features of ADS� Intrinsically-Safe TRITON+® and the methods of installation, operation, and maintenance.
The ADS TRITON+ is an intrinsically-safe flow monitor that measures open-channel flow depth and velocity to determine flow rate in sanitary sewers, storm sewers, combined sewers, and other environments. The manual covers intrinsic safety and certification, system components, communication, configuration and activation, sensor installation, external power, monitor installation, analog and digital I/O, Modbus, and maintenance and troubleshooting.
It provides detailed instructions for installing, operating, maintaining, and troubleshooting the TRITON+ monitor, sensors, and communication hardware. The monitor is identified as Model 8000-FST-IM and is certified to IECEx and ATEX standards for Zone 0 hazardous areas.
| Monitor model | 8000-FST-IM |
|---|---|
| Measurement parameters | Open-channel flow depth and velocity |
| IECEx certification | IECEx |
| ATEX certification | ATEX Zone 0 |
| Analog input signal | 4-20 mA |
| Analog input loop load | 22 ohms |
It measures open-channel flow depth and velocity to determine flow rate in pipes.
Yes. It is certified under ATEX standards for Zone 0 and tested to worldwide IECEx standards.
The TRITON+ flow monitor is Model 8000-FST-IM.
The XIO input adds 22 ohms to the loop.