This manual introduces the repair parts and maintenance instructions of 32 Gem•2® Flushometer 6A
This document serves as a repair parts and maintenance guide for the Sloan Geme2 Flushometer. It includes detailed parts lists for various components such as piston kits, vacuum breakers, spud couplings, and handle assemblies, distinguishing between new and old style adjustable models.
The guide also features a troubleshooting section addressing common issues like valve malfunction, insufficient water volume, and leaking, along with specific care and cleaning instructions to maintain the chrome finish.
| Product Type | Flushometer |
|---|---|
| Water Closet Flow (Low Consumption) | 1.6 gpf / 6.0 Lpf |
| Urinal Flow (Low Consumption) | 1.0 gpf / 3.8 Lpf |
| Water Closet Flow (Standard) | 3.5 gpf / 13.2 Lpf |
Pistons can be identified by the color, shape, and marking of the barrel, cover, and stem components.
Use the A-50 Super-Wrench or other smooth-jawed wrenches; do not use toothed tools.
Use only mild soap and water, then wipe dry with a clean cloth or towel.