This document is the operator's manual for INVERTEC® V160, which introduces the product's usage methods, precautions, etc.
The document is an operator's manual for the Lincoln Electric INVERTEC V160 welding machine, published by Lincoln Electric Italia S.r.l. It includes multilingual sections covering safety warnings, declaration of conformity, and installation instructions.
Key operational details include specific requirements for connecting to power grids and autonomous generators (V160 2V), as well as procedures for setting up Manual Metal Arc (MMA) welding with correct polarity connections.
| Input Voltage RMS (V160) | 230Vac ± 15% |
|---|---|
| Input Voltage RMS (V160 2V) | 115Vac or 230 Vac ± 10% |
| Protection Class | IP23S |
The RMS input voltage must be 230Vac ± 15%.
Yes, provided the generator supplies 230Vac auxiliary power and meets specific voltage and frequency conditions.
The machine has a protection degree of IP23S.