This is a service manual for iC-PW1 HF/50 MHz ALL BAND LINEAR AMPLIFIER
The document serves as a technical guide for servicing the ICOM IC-PW1 HF/50 MHz All Band Linear Amplifier. It covers safety precautions regarding high voltage and weight handling before beginning any work.
Key sections include detailed specifications such as frequency ranges (1.8-54 MHz) and output power capabilities, alongside inside views of the unit's internal components like the Splitter, PA, Combiner, and Tuner units.
| Frequency range | 1.800-1.999 MHz, 3.500-3.999 MHz, 4.630 MHz, 7.000-7.100 MHz, 10-100-10-150 MHz, 14.000-14.350 MHz, 18.068-18.168 MHz, 21.000-21.450 MHz, 24.890-24.990 MHz, 28.000-29.700 MHz, 50.000-54.000 MHz |
|---|---|
| Duty cycle | Full duty |
| Input connector | $O-239 x 2 (50 Q) |
| Output connector | $0-239 x 4 (50 Q) |
| Power supply voltage | 90 V-132 V AC or 180 V-264 V AC |
| Usable temperature range | -10°C to +40 °C; +14 °F to +104 °F |
| Weight | 25 kg; 55.12 Ib |
The output power is 450-600 W PEP at 90-132 V AC and 950-1150 W PEP at 180-264 V AC.
The auto tuning accuracy ensures an SWR of 1.5:1 or less.
The minimum required input power is 60W.