This manual describes the installation, operation and maintenance of the e-SV series pumps.
This document serves as the official installation, operation, and maintenance manual for the Goulds e-SV product line of vertical multistage, non-self priming pumps. It covers various configurations including liquid end only and pump & motor combinations, detailing the product numbering system, safety instructions, and operational procedures.
The manual outlines the scope of the e-SV pump, which is suitable for civil and industrial water distribution systems, pressure boosting, irrigation, water treatment, and fire fighting applications. It provides specific instructions for pre-installation checks, transportation, installation steps, start-up, daily operation, and routine maintenance, including mechanical seal replacement and motor replacement procedures.
| Product Type | Vertical multistage, non-self priming pump |
|---|---|
| Coupling | Standard electric motors |
| Seal Design | Special mechanical seal for easy replacement |
| Material Contact | Stainless steel or cast iron |
The e-SV pump is a vertical multistage, non-self priming pump that can be coupled to standard electric motors.
Some metal parts in contact with the pumped liquid are made of stainless steel, while others are made of cast iron.
Yes, the pump is equipped with a special mechanical seal designed for easy replacement without disassembling the entire pump.