Goulds 2AM32-P Petroleum Pump Installation Operation and Maintenance Instructions

Marlow Series 2AM32-P PETROLEUM PUMP INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS. This manual contains information on operation, maintenance, recommended precautions and troubleshooting guide.


Goulds 2AM32-P Petroleum Pump Installation Operation and Maintenance Instructions - cover page
Brand
Goulds
Category
Other products
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
311 KB
Published
15 October, 2023
Updated
15 October, 2023
Model
2AM32-P
MD5 checksum
19C19A74FEC72F7DD9F1D6521D7EAC9F

About this manual

This manual provides instructions for the Goulds 2AM32-P petroleum pump, designed for pumping diesel fuel, jet fuel, or gasoline in well-ventilated areas. It emphasizes safety precautions regarding volatile petroleum products and the use of non-sparking tools and grounded connections.

What's inside

  • Operating and Safety Instructions
  • Maintenance Instructions
  • Recommended Precautions
  • Operating Instructions
  • Troubleshooting Guide
  • Repair Parts
  • Limited Warranty

Specifications

Applicationpetroleum products such as diesel fuel, jet fuel or gasoline
Maximum Pressure75 psi
Temperature Limit50ºF above ambient

Frequently asked questions

What liquids is this pump designed for?

The pump is designed to pump petroleum products such as diesel fuel, jet fuel, or gasoline, as well as water.

What safety precaution is required before operating the pump?

Always securely connect the ground wire to a good ground on the tank being filled before operating the pump.

How should the pump be maintained if not used for several days?

Drain all the liquid from the tank when the pump is not in use for several days or for winter storage.

Download PDF (311 KB)