This document is about the safety instructions of ITT Goulds Pumps pumps, including safety use methods and precautions.
This document serves as a safety manual for the ITT Goulds Pumps JCU model. It outlines critical safety warnings and precautions regarding the installation, operation, and maintenance of the pump to ensure the safety of personnel and the environment. The manual emphasizes that the user is responsible for following industry standards and corporate safety guidelines in addition to the specific instructions provided here. This manual is written in Spanish.
The manual uses ADVERTENCIA for situations that may cause death or serious injury, PRECAUCIÓN for situations that may cause minor or moderate injuries, PELIGRO ELÉCTRICO for electrical risks, and ATEX for potentially explosive atmospheres.
No, applying heat to extract an impeller is strictly prohibited because trapped liquid can expand rapidly and cause a violent explosion.
The motor power supply must always be blocked before performing any maintenance to prevent accidental start-up and physical injuries.