ITT Goulds Pumps PS20 Shaft Power Monitor Installation, Operation and Maintenance Manual

This manual describes installation, operation and maintenance of the PS20 motor controller


ITT Goulds Pumps PS20 Shaft Power Monitor Installation, Operation and Maintenance Manual - cover page
Brand
ITT Goulds Pumps
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
54
File format
PDF
File size
943 KB
Published
15 October, 2023
Updated
15 October, 2023
MD5 checksum
C2FF1A1BE99FC4F55A97F83D3B8A4272

About this manual

The ITT Goulds Pumps PS20 is a shaft power monitor designed to supervise induction motor driven equipment, such as pumps and mixers. It calculates shaft power by measuring motor input power and subtracting calculated motor power losses, providing accurate monitoring of the actual application load. The device features a display for load indication and parameter setting, allowing for both overload and underload protection with programmable alarm levels and response delays.

What's inside

  • Inside the Box
  • Safety
  • Description
  • Getting Started
  • Wiring
  • Selection of Current Transformer
  • Operation
  • Programming
  • Advanced Features
  • Troubleshooting

Specifications

Dimensions45x90x115 mm (1.77" x 3.54" x 4.53")
Mounting35 mm DIN rail
Weight0.30 kg (10.5 oz)
Supply voltage1x100 -240 VAC, 3x100 -240 VAC, 3x380 -500 VAC or 3x525- 690 VAC
Frequency50 or 60 Hz
Current inputCurrent transformer; CTM 010, 025, 050 and 100. Input 0-55 mA
Power consumptionMax. 6 VA
Start-up delay1-999 s
Relay output5 A/240 VAC Resistive, 1.5 A/240 VAC Pilot duty/AC12
Analogue output Max. load500 ohm
Digital inputMax. 240 VAC or 48 VDC

Frequently asked questions

What applications is the PS20 monitor ideal for?

The PS20 is ideal for protecting many different applications including pumps in general, centrifugal pumps, magnetic pumps, screw and impeller pumps, mixers, scrapers, crushers, and conveyor systems.

How does the PS20 calculate shaft power?

The monitor calculates shaft power by measuring motor input power and subtracting the motor power loss calculated using a unique principle.

What is the maximum response delay for the PS20?

The maximum response delay is 500 seconds.

What happens if the seal on the housing is removed?

Removing or tampering with the seal on the housing will invalidate the warranty.