ITT Goulds Pumps Manuals

ManualLib has 10 ITT Goulds Pumps manuals. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 3User Manual 5Service Manual 2

Key facts

Manuals
10
Languages
EN · ES
Last added
2026-11-01

Latest ITT Goulds Pumps manuals

Which document do I need?

User Manual

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Service Manual

Disassembly, diagnostics and part numbers, for repair.

Questions answered in ITT Goulds Pumps manuals

What is the maximum solids handling capability?

The pumps can handle solids up to ¾" in diameter.

From: ITT Goulds Pumps EP04 & EP05 Series Model 3871 Submersible Effluent Pumps Product Leaflet

Can the pump run dry without damage?

Yes, the pump is capable of running dry without damage to components.

From: ITT Goulds Pumps EP04 & EP05 Series Model 3871 Submersible Effluent Pumps Product Leaflet

What is the maximum temperature the pump can handle?

The maximum temperature the pump can handle is 140°F.

From: ITT Goulds Pumps JS+ Shallow Well Jet Pumps J5S, J5SH, J7S, J10S, J15S

What is the motor's rotation direction?

The motor rotates clockwise when viewed from the motor end.

From: ITT Goulds Pumps JS+ Shallow Well Jet Pumps J5S, J5SH, J7S, J10S, J15S

What are the different safety terms used in this manual?

The manual uses ADVERTENCIA for situations that may cause death or serious injury, PRECAUCIÓN for situations that may cause minor or moderate injuries, PELIGRO ELÉCTRICO for electrical risks, and ATEX for potentially explosive atmospheres.

From: ITT Goulds Pumps JCU Pump Safety Manual

Can heat be applied to remove an impeller?

No, applying heat to extract an impeller is strictly prohibited because trapped liquid can expand rapidly and cause a violent explosion.

From: ITT Goulds Pumps JCU Pump Safety Manual