This document introduces the basic principles, operating conditions, installation process and other information of DuPont™ EDI-310 module
The document describes the DuPont EDI-310 module, which utilizes spiral wound membrane technology combining ion exchange resin and direct current (DC) to deionize water. This process eliminates the need for hazardous chemical regeneration found in traditional systems by continuously regenerating resins using electrolytic splitting of water molecules.
| Temperature Range (Storage) | 4° C to 38° C (40° F to 100° F) |
|---|---|
| Maximum Feed Pressure | 6.9 bars (100 psig) |
It utilizes spiral wound membrane technology which combines ion exchange resin, ion selective membranes, and direct current (DC) to deionize water.
The module must be stored between 4° C (40° F) and 38° C (100° F).
Do not operate the module continuously at a feed pressure higher than 5.5 bars (80 psig).