This is an installation and operation manual for a liquid dilution system. The system can be activated by twisting and locking, and is suitable for mop buckets and spray bottles.
This manual provides installation and operation instructions for the Ecolab Liquid Dilution System (LDS), a device that dispenses diluted cleaning and sanitizing solutions. The system operates by mixing concentrated product with water when a button is pressed, utilizing either an E Gap or Air Gap backflow prevention method depending on local plumbing codes.
| Height | 253 mm / 9.96 in |
|---|---|
| Width | 90 mm / 3.54 in |
| Depth (button not pressed) | 178 mm / 7.00 in |
| Depth (button pressed) | 162 mm / 6.38 in |
| Weight | 591 grams / 1.30 lbs |
| Minimum water pressure | 20 PSI |
| Maximum water pressure | 85 PSI |
| Maximum water temperature (floor care) | 140°F (60°C) |
The system supports both E Gap and Air Gap backflow prevention methods, with the Air Gap required by some plumbing codes.
The maximum water temperature should not exceed 140°F (or 60°C) for floor care.
You must use at least three mounting screws to fully secure the Liquid Dilution System (LDS) to the wall.
A water source with a minimum static pressure of 20 PSI is required.