This manual provides instructions for the installation, operation, and maintenance of the Mega 960D pump
The Trebor Mega 960D Pump Operation and Maintenance Manual covers the complete lifecycle of the pump, from unpacking and installation to startup and maintenance. It details the required utilities, such as air supply pressure and fluid port connections, and provides specific torque values for tie bolts and fittings to ensure proper assembly.
| Maximum supply CDA/N2 pressure | 80 psig (5.5 bar) |
|---|---|
| Maximum fluid temperature | 212°F (100°C) |
| Air Supply Pressure Range | 25-80 psig (1.4 - 4.1 bar) |
| Air Inlet Size | 1/2" FNPT |
| Remote Exhaust Size | 1/4" FNPT |
| Mounting Bolt Size | four 1/4" bolts |
Apply 60 in-lbs. of torque to each slave side bolt while holding the master side bolt stationary.
The minimum air supply pressure setting is 20 psig.
Prolonged periods of dry running greater than 5 minutes will damage critical internal pump parts.
The maximum fluid temperature is 212°F (100°C).