This manual provides instructions on the installation, operation, and maintenance of the MAXIM 50E/U pump.
This document serves as the Operation and Maintenance Manual for the Trebor 50E/U pump. It covers the complete lifecycle of the device, starting with unpacking and installation, including specific procedures for probe assembly and PLC control schematics. The guide details how to hook up utilities such as air supply and fluid ports, ensuring proper torque and clearance for optimal performance.
| Air Supply Pressure | 20-80 psig (1.4 – 5.5 bar) |
|---|---|
| Air Inlet Size | 1/4” FNPT |
| Minimum Exhaust Clearance | 1/2” (12mm) |
| Damper Port Plug Torque | 50 in-lbs |
| Union Nut Torque | 75 ft-lbs |
| Minimum Air Pressure for Operation | 15 psi |
The pump requires clean dry air or nitrogen at a pressure between 20-80 psig (1.4 – 5.5 bar).
The exhaust locations require a minimum clearance of 1/2” (12mm) behind the control base.
The Damper Port Plug should be torqued to 50 in-lbs using a 3/4” pin tool and a torque wrench.
The pump requires a minimum of 15 psi at the pump air hook-up to start.