This manual provides installation, operation, maintenance, troubleshooting, and spare parts information for the Trebor EVOLVE 55E pump.
The document serves as an operation and maintenance guide for the Trebor EVOLVE 55E pump. It covers essential procedures including unpacking, utility connections, optional end-of-stroke probe installation, remote exhaust setup, and start-up instructions with performance charts.
Detailed sections are provided for preventive maintenance schedules, recommended spare parts lists, disassembly and assembly steps, cleaning procedures, testing protocols, and a comprehensive troubleshooting guide for common issues such as pump failure, fluid leaks, and erratic cycling.
| Air Supply Pressure Range | 20-100 psig (.14 - .69 MPa) |
|---|---|
| Air Inlet Size | 1/4" FNPT |
| Minimum Air Supply Tube Diameter | 3/8" Dia. [8mm] |
| Damper Port Plug Torque | 50 in-lbs |
| Union Nut Torque | 125 ft-lbs |
The pump requires a minimum of 15 psi at the pump air hook-up.
The pump must be operated with clean, dry air or nitrogen to prevent damage from particulates.
Trebor recommends that the Damper Port be torqued upon pump installation.
To maintain optimum performance, use a maximum length of 10 ft. (3 meters) for remote exhaust.