This document is a revised version of the user manual for CH260, CH270, CH395, and CH440 engines from KohlerEngines.com. The document includes safety precautions and instructions for equipment operation, warranty coverage, and important tips. It also provides guidance on recording engine information and includes a warning based on California Proposition 65.
This user manual covers the operation and maintenance of Kohler CH260, CH270, CH395, and CH440 engines. It includes critical safety warnings regarding fuel handling, hot parts, rotating components, and carbon monoxide exposure to prevent injury or death.
The document details pre-start checks, starting procedures for both cold and warm engines, and specific instructions for cold weather operation. It also outlines a comprehensive maintenance schedule based on engine hours (e.g., oil changes every 50 hours) and provides recommendations for selecting the correct viscosity lubricant based on atmospheric temperature. This manual is written in Chinese.
You must change the oil every 50 hours for these specific models.
The engine is designed to run normally below 4000 ft (1219 m).
You must wait 60 seconds before trying to start the engine again.