The manual identifies the Audi A3 e-tron by its e‑tron logo and outlines safety warnings for the high‑voltage system, including the need to secure the vehicle and avoid contact with high‑voltage components. It describes the vehicle’s high‑voltage architecture (324 V DC, up to 400 V AC) and the location of safety labels.
Detailed procedures cover deactivating the drive and high‑voltage systems from both the passenger compartment and the engine compartment, disconnecting the charging cable, fire‑fighting measures for lithium‑ion battery incidents, and reporting requirements for test‑vehicle accidents. This manual is written in Chinese.
| High‑voltage system voltage | 324 V DC (up to 400 V AC) |
|---|---|
| Auxiliary battery | 12 V |
| High‑voltage fuse | Fuse number 39 (red, yellow marking) |
Turn the ignition key to OFF and remove it, open the fuse panel, and pull the red fuse number 39; the system disables after about 15 seconds.
Stop the charging process at the charging station, then disconnect the charging connector from the vehicle.
Use a large amount of water, foam, or CO₂ to extinguish the fire.
Inform the responsible dispatch center immediately, which will forward the information to the police.