STMicroelectronics DCPL-WB-00D3 Wide-band Dual-path Directional Coupler Datasheet

The DCPL-WB-00D3 is a wide-band, dual-path directional coupler with ISO port designed to measure cell phone transmission output power in GSM/WCDMA applications. This dual path CPL has been customized for wide-band operating frequencies (EGSM and CELL, PCS, DCS, WCDMA band I) with less than 0.2 dB insertion losses in the transmission bandwidth (824 MHz - 1980 MHz).


STMicroelectronics DCPL-WB-00D3 Wide-band Dual-path Directional Coupler Datasheet - cover page
Brand
STMicroelectronics
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
11
File format
PDF
File size
138 KB
Published
09 August, 2012
Updated
30 September, 2023
MD5 checksum
44B067D5386D282F5ABEECCF3C959855

About this manual

The DCPL-WB-00D3 is a wide-band, dual-path directional coupler designed to measure cell phone transmission output power in GSM/WCDMA applications. It utilizes STMicroelectronics IPD technology on a non-conductive glass substrate and is delivered in a lead-free Flip Chip package with a small footprint of 1670 x 1440 um and a thickness of less than 650 um.

The device features two different RF couplers (one for Low Band and one for High Band) sharing the same coupled and isolated ports. It offers a wide operating frequency range from 824 MHz to 2170 MHz, with low insertion loss (< 0.2 dB) and high directivity (> 20 dB). The component complies with IEC 61000-4-2 level 4 standards for ESD ruggedness.

What's inside

  • Features
  • Applications
  • Description
  • Pin Configuration
  • Absolute Maximum Ratings
  • Electrical Characteristics
  • Package Information
  • Ordering Information

Specifications

Operating Frequency Range824 MHz - 2170 MHz
Insertion Loss< 0.2 dB
Directivity> 20 dB
Nominal Impedance50 Ohm
Package TypeLead-free Flip Chip (8 bumps)
Footprint Dimensions1670 x 1440 um
Operating Temperature-30 to +85 °C
Air Discharge ESD Rating+15 kV

Frequently asked questions

What is the nominal impedance of the coupler?

The nominal input and output impedance is 50 Ohms.

What is the DCPL-WB-00D3 designed to measure?

The device is designed to measure cell phone transmission output power in GSM/WCDMA applications.

What are the operating frequency ranges for the low and high band paths?

The low band path operates from 824 MHz to 960 MHz, while the high band path operates from 1710 MHz to 1980 MHz.