This document is a manual for SEW-EURODRIVE's MOVITRAC® 07 Communication product. The manual provides information on the technical data, communication functions, installation, operation, and service of the product.
This document serves as a communication guide for the SEW MOVITRAC 07 frequency inverter series. It details the technical data for the System Bus (SBus) and the MOVILINK profile, explaining how these units function as slaves or masters in automation systems. The manual describes the capabilities of the MOVILINK profile for automation, drive control, and parameter setting, noting that standard design units operate only as slaves while LOGODrive units can serve as masters.
| Baud rate | 125, 250, 500 or 1000 kbaud |
|---|---|
| ID range | 0 ... 2047 |
| Address range | 0 ... 63 |
| Number of process data words | 3 |
| Max cable length (125 kbaud) | 320 m |
| Max stations | 64 |
No, units in standard design can only be operated as slaves.
The factory setting for the baud rate is 500 kbaud.
The UFx11A fieldbus gateways allow integration into PROFIBUS-DP, INTERBUS, DeviceNet, and CANopen systems.