This application note describes the design for a single-phase power / energy meter with tamper detection.
The document details a cost-effective and flexible design for a single-phase power and energy meter that fulfills IEC 61036:1996 + A1: 2000 standards. It utilizes the ST7FLITE20 microcontroller to perform all measurements and calculations without an external dedicated device (ASSP). The design measures active power, voltage, current, power factor, and line frequency in a single-phase distribution environment.
| Standards Compliance | IEC 61036:1996 + A1: 2000 |
|---|---|
| Current Rating (Ib) | 10A |
| Maximum Current (Imax) | 55A |
| Voltage Range | 140V to 300V |
| Sampling Rate | 5kHz |
| Sampling Time | 200us |
| Pulse Output | 32 000 Impulses/kWh |
| ADC Resolution | 10-bit SAR |
The ST7FLITE20 microcontroller is used to perform all the measurements in the meter.
It uses two current transformers (CT) to measure active power in both live and neutral wires to detect tamper attempts.
Yes, the firmware can be modified and updated at any time using In-Circuit Programming, even when the meter is installed and running.