DAIKIN FHQ18PVJU FHQ24PVJU FHQ30PVJU Manual

This document is about the instruction manual of FHQ18PVJU, FHQ24PVJU, FHQ30PVJU type ceiling suspended air conditioners.


DAIKIN FHQ18PVJU FHQ24PVJU FHQ30PVJU Manual - cover page
Brand
Daikin
Category
Air conditioner
Document type
Installation Guide
Language
English
Pages
16
File format
PDF
File size
1.5 MB
Published
06 August, 2012
Updated
01 October, 2023
MD5 checksum
AD3D3BE914B5E814C89E3DCEB19663DB

About this manual

This document serves as the installation guide for Daikin Split System Air Conditioners of the ceiling suspended type. It covers safety considerations, site selection, preparation, and detailed instructions for installing both indoor and outdoor units, along with refrigerant piping and wiring work.

The manual provides specific guidelines on handling electrical connections, remote controller setup, and attaching suction grilles and decoration panels. It also includes sections for field setting and test operation to ensure the unit functions correctly after installation.

What's inside

  • Safety Considerations
  • Before Installation
  • Selecting Installation Site
  • Preparations Before Installation
  • Indoor Unit Installation
  • Refrigerant Piping Work
  • Drain Piping Work
  • Wiring Example and Remote Controller Setup
  • Field Setting
  • Test Operation

Frequently asked questions

What is the minimum distance required from televisions or radios during installation?

Install the indoor and outdoor units, power supply wire, and transmission wire at least 3.5 ft. away to prevent image interference or noise.

How long must one wait before turning off the power after stopping operation?

You must always wait at least 5 minutes before turning off the power to avoid water leakage and trouble.