This document is the Geyser Main Drain Instructions, which introduces the installation and usage methods of the product.
This document provides installation instructions for the Pentair Geyser Main Drain, a pool component designed to minimize body entrapment risks. It details the correct plumbing configuration, emphasizing that the inlet port connects to the filter line and the outlet port connects to the pump suction. The manual includes specific warnings regarding flow rates and the prohibition of valves on the inlet line to prevent entrapment hazards.
| Maximum suction flow rate | 85 GPM |
|---|---|
| Part Number | P/N 500019 |
| Document Revision | Rev. D |
The inlet port (side port) must be connected to the filter line supplying filtered water, and the outlet port (bottom port) must be connected to the pump suction returning unfiltered water.
No, you must not add a valve to the inlet line of the Main Drain, as this can result in hair or body entrapment.