This document explains the design, installation methods, precautions and other aspects of Xport Drain System.
This guide provides installation instructions for the Pentair Xport Series drain system, designed for use in concrete, fiberglass, and vinyl pools. It emphasizes critical safety precautions regarding entrapment risks and specifies a maximum flow rate of 90 GPM. The document outlines the required installation of a second suction outlet and approved vacuum breaker methods specific to each pool type.
| Maximum Flow Rate | 90 GPM |
|---|---|
| Required Pipe Length | 18 inches |
| Required Pipe Diameter | 2 inches |
The system is rated for a maximum of 90 GPM to prevent entrapment hazards.
At least two suction outlets must be installed for each pump in the plumbing system.
Covers must be approved to the ANSI/ASME A112.19.8 Standard.