Known bugs, anomalies and work-arounds for the ADuC812 MicroConverter
This document serves as an errata sheet for the Analog Devices ADuC812 MicroConverter, detailing known bugs, anomalies, and work-arounds. It applies to all ADuC812 packaged material and is periodically updated to reflect silicon revisions and improved work-arounds.
The sheet covers specific functional issues including ADC conversion in DMA mode, UART multiprocessor communications, Port 2 internal pull-up functionality, Flash/EE memory programming at low temperatures, baud rate generation in split timer mode, power supply trip indicators, and external power-on reset operations. It provides specific work-arounds for each identified issue.
| Internal Code Space | 8 KBytes |
|---|---|
| Flash/EE Data Memory | 640 Bytes |
| Operating Temperature Range | -40°C to 85°C |
Ensure that the correct configuration sequence is used for the ADC, i.e. configure ADCCON2 then ADCCON1.
Ensure that the DMA start address is set to 000000H.
No, this revision of silicon will not support programming below DV DD=3V supplies in that temperature range.