Analog Devices ADuC812 MicroConverter Errata Sheet

Known bugs, anomalies and work-arounds for the ADuC812 MicroConverter


Analog Devices ADuC812 MicroConverter Errata Sheet - cover page
Brand
Analog Devices
Category
microcontrollers
Document type
Other
Language
English
Pages
4
File format
PDF
File size
58 KB
Published
03 August, 2012
Updated
30 September, 2023
Model
ADUC812
MD5 checksum
C2E2DA1282E08D095EE333DFA26E6F7F

About this manual

This document serves as an errata sheet for the Analog Devices ADuC812 MicroConverter, detailing known bugs, anomalies, and work-arounds. It applies to all ADuC812 packaged material and is periodically updated to reflect silicon revisions and improved work-arounds.

The sheet covers specific functional issues including ADC conversion in DMA mode, UART multiprocessor communications, Port 2 internal pull-up functionality, Flash/EE memory programming at low temperatures, baud rate generation in split timer mode, power supply trip indicators, and external power-on reset operations. It provides specific work-arounds for each identified issue.

What's inside

  • ADC Function
  • UART Function
  • Port 2 Internal Active Pull-Up
  • Flash/EE Memory
  • UART Functionality
  • PSMCON.1 Bit Functionality
  • External Power-On Reset
  • Reset Functionality

Specifications

Internal Code Space8 KBytes
Flash/EE Data Memory640 Bytes
Operating Temperature Range-40°C to 85°C

Frequently asked questions

What is the work-around for Timer2 triggered DMA conversions?

Ensure that the correct configuration sequence is used for the ADC, i.e. configure ADCCON2 then ADCCON1.

How should the DMA start address be set for Timer2 triggered conversions?

Ensure that the DMA start address is set to 000000H.

Can the device be programmed below 3V in the -40°C to 0°C range?

No, this revision of silicon will not support programming below DV DD=3V supplies in that temperature range.