This application note details how to implement a complete RTD sensor interface using the Analog Devices ADuC834 MicroConverter and a few passive components. It covers hardware design, signal conditioning, A/D conversion, linearization, and calibration methods for platinum RTD sensors.

What's inside

  • Introduction
  • Hardware Design
  • Calculating RTD Resistance from ADC Result
  • RTD Transfer Function
  • Linearization Techniques
  • Calibration

Specifications

Temperature Range-200°C to +850°C
Calibrated Accuracy±0.02°C or better
ADC Resolution16-bit or 24-bit
Microcontroller Core8052 MCU
Reference Resistor Value5.62 kΩ
RTD Nominal Resistance100 Ω at 0°C
ADC Gain Setting7.8125
ADC0CON Value0x4C

Frequently asked questions

What is the temperature range for platinum RTDs?

Platinum RTDs can measure temperature within the range –200°C to +850°C.

What is the calibrated accuracy of platinum RTDs?

They are capable of achieving calibrated accuracy of ±0.02°C or better.

Which MicroConverter device is used in this application note?

The application note describes using the ADuC834 (or other similar MicroConverter).