AN-636 APPLICATION NOTE ADN2819 Evaluation Board
The document provides a quick start guide for operating the ADN2819 evaluation board in OC-48 normal operating mode. It details the power supply requirements, data rate selection via switches, and the configuration of the reference clock using either the on-board crystal or an external source.
| Supported Data Rates | SONET OC-3, OC-12, OC-48, Gigabit Ethernet |
|---|---|
| Supply Voltage | 3.3 V nominal |
| Loop Filter Capacitance | 4.7 μF |
| Input Coupling Capacitance | 1.8 μF |
Set all switches S1 through S9 to the 0 position to use the on-board 19.44 MHz crystal as the reference clock.
The input signal must provide a differential input of greater than 10 mV.
Set REFSEL switch S1 to 1 to disconnect the on-board oscillator and connect an external clock to the REFCLKP/REFCLKN pins.