Analog Devices CN-0271 K-Type Thermocouple Measurement System Application Note

CN-0271 is a K-type thermocouple measurement system composed of AD8495, AD8476, AD7790, ADR441 with integrated cold junction compensation.


Analog Devices CN-0271 K-Type Thermocouple Measurement System Application Note - cover page
Brand
Analog Devices
Category
Other Electronics
Document type
Application Note
Language
English
Pages
5
File format
PDF
File size
554 KB
Published
02 August, 2012
Updated
30 September, 2023
MD5 checksum
92EB178038B9F1A820DAA340F325AE6B

About this manual

The document details a complete thermocouple signal conditioning circuit designed for measuring K-type thermocouple temperatures. The system utilizes the AD8495 amplifier for cold junction compensation and signal amplification, driving an AD7790 16-bit sigma-delta ADC via an AD8476 differential amplifier. The circuit provides a compact, low-cost solution for high-resolution analog-to-digital conversion.

What's inside

  • Circuit Function and Benefits
  • Circuit Description
  • Test Results
  • Common Variations
  • Circuit Evaluation and Test
  • Equipment Needed
  • Getting Started
  • Functional Block Diagram

Specifications

Temperature Range15°C to 950°C
Output Voltage Calibration5 mV/°C
ADC Resolution16-bit
Noise Free Resolution13.4 bits
Linearity Errorwithin 2°C
System Error with Correctionwithin 1°C

Frequently asked questions

What is the temperature range for the CN-0271 system?

The system is calibrated for a temperature range of 15°C to 950°C.

How does the circuit handle cold junction compensation?

The AD8495 thermocouple amplifier provides integrated cold junction compensation.

What is the noise free resolution of the system?

The measured noise free resolution is approximately 13.4 bits.