Agilent 1200 Infinity Series HDR-DAD Solution - Extend your insight with a 30x wider linear UV-range

Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector Solution gives you a linear UV-range more than 30 times wider than before, you can detect and quantify all components in your sample in a single run.


Agilent 1200 Infinity Series HDR-DAD Solution - Extend your insight with a 30x wider linear UV-range - cover page
Brand
Agilent
Category
Other
Document type
Product Leaflet
Language
English
Pages
4
File format
PDF
File size
1.2 MB
Published
03 July, 2012
Updated
30 September, 2023
MD5 checksum
19CA17869A95C98109394445C12ACE44

About this manual

The Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector (DAD) solution expands UV-detection capabilities by combining signals from two diode array detectors fitted with different path length flow cells. One detector uses a 3.7 mm path length for high concentrations, while the other uses a 60 mm path length for low concentrations. Specially developed algorithms correct for retention time differences to compute signals that expand the linear dynamic range by a factor of 30 compared to earlier generation detectors.

This solution allows users to detect and quantify all components in a sample in a single run, eliminating the need for reanalysis, recalibration, or additional sample preparation steps like dilution. It extends the upper linearity level to typically 6 absorbance units, enabling the injection of 3 times more sample while benefiting from lower detector noise. This provides up to 30 times higher sensitivity for the simultaneous analysis of main compounds and impurities, particularly useful in pharmaceutical and chemical industries.

What's inside

  • High Dynamic Range DAD Solution
  • 30x wider linear UV-range
  • Two diode array detectors
  • Max-Light flow cells
  • Impurity analysis
  • Optofluidic waveguides
  • Sample turnaround time
  • Automated peak integration

Specifications

Linear UV-range expansion factor30 times wider than earlier generation
Upper linearity leveltypically 6 absorbance units
Sample injection increase3 times more sample
Detector noise reduction10 times lower detector noise
Sensitivity increaseup to 30 times higher sensitivity
Flow cell path lengths3.7 mm and 60 mm

Frequently asked questions

What is the benefit of the 30x wider linear UV-range?

It allows you to detect and quantify all components in your sample in a single run, eliminating the need for reanalysis or sample dilution.

How does the solution handle samples with different concentration levels?

It combines signals from two detectors with different path lengths: a 3.7 mm cell for high concentrations and a 60 mm cell for low concentrations.

What is the upper linearity level of the new solution?

The solution extends the upper linearity level to typically 6 absorbance units.

Who is the ideal user for this solution?

It is ideal for impurity analysis of samples with highly different concentrations of active components, such as fixed-dose combinations in pharmaceutical drugs.