Linear Technology LT1002 Dual Operational Amplifier Datasheet

LT1002 is a dual-channel, high-precision operational amplifier suitable for thermocouple amplifiers, strain gauge amplifiers, low-level signal processing, medical instrumentation, etc. It features low offset voltage, low drift, high common mode rejection ratio, and high channel separation.


Linear Technology LT1002 Dual Operational Amplifier Datasheet - cover page
Brand
Linear Technology
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
16
File format
PDF
File size
345 KB
Published
05 June, 2012
Updated
28 September, 2023
Model
LT1002
MD5 checksum
054845BDE6A37615C2E8F9456B6590B8

About this manual

The document describes the LT1002, a dual matched precision operational amplifier designed to combine excellent individual performance with tight matching and temperature tracking between amplifiers. It is optimized for applications requiring high precision, such as thermocouple amplifiers, strain gauge amplifiers, low-level signal processing, and medical instrumentation.

The datasheet provides absolute maximum ratings, detailed electrical characteristics for various grades (LT1002A, LT1002M, LT1002C), matching characteristics between the two channels, and typical performance graphs including offset voltage distribution, noise spectrum, and long-term stability.

What's inside

  • Features
  • Applications
  • Description
  • Absolute Maximum Ratings
  • Package/Order Information
  • Electrical Characteristics
  • Matching Characteristics
  • Typical Performance Characteristics

Specifications

Input Offset Voltage (LT1002A)60uV max
Input Offset Voltage Match (LT1002A)40uV max
Input Noise Voltage Density9.6 nV/√Hz (typ)
Common Mode Rejection Ratio110dB min
Channel Separation132dB min (LT1002A)
Operating Temperature Range (Grade A)-55°C to +125°C

Frequently asked questions

What are the applications for the LT1002?

The device is suitable for thermocouple amplifiers, strain gauge amplifiers, low level signal processing, medical instrumentation, and precision dual limit threshold detection.

What is the maximum input offset voltage for the LT1002A?

The guaranteed maximum input offset voltage for the LT1002A is 60uV.

How does the power dissipation of the LT1002 compare to other precision duals?

The power dissipation is nearly halved compared to the most popular precision duals without adversely affecting noise or speed performance.