Linear Technology LT3800 High Voltage Current Mode Step-Down Converter Design Note 383


Linear Technology LT3800 High Voltage Current Mode Step-Down Converter Design Note 383 - cover page
Brand
Linear Technology
Category
DC/DC Converter
Document type
Application Note
Language
English
Pages
2
File format
PDF
Published
05 June, 2012
Updated
29 September, 2023
Model
LT3800
MD5 checksum
E1E40C5FF66B17A773BFC3DEDEB12C35

About this manual

Design Note 383 by Jay Celani introduces the LT3800 as the core of a single-supply synchronous DC/DC converter for systems requiring high input voltages and substantial load currents. The note says the LT3800 is a 4V to 60V, 200kHz fixed-frequency controller that uses synchronous operation and N-channel MOSFETs, current mode operation with high-side inductor current sensing, and Burst Mode operation for low current standby.

The document presents a 12V, 75W synchronous buck DC/DC converter operating from 20V to 55V input, with full-load efficiencies above 95% and 0.1mA input supply quiescent current at no load. It also describes programmable UVLO, controlled soft-start at 1.3V/ms, current limiting during short-circuit conditions, and measured load-step transient response.

What's inside

  • Introduction
  • High Efficiency at Standby
  • 12V/75W Synchronous Buck DC/DC Converter

Specifications

Input voltage range4 V to 60 V
Switching frequency200 kHz
Controller operationSynchronous operation with N-channel MOSFETs
No-load input supply quiescent current0.1 mA
Example converter output12 V, 75 W
Example converter input voltage20 V to 55 V
Full-load efficiencyAbove 95%
Peak conversion efficiencyAs high as 96%
Load-step transientLess than 2% Vout

Frequently asked questions

What input voltage range does the LT3800 support?

The LT3800 is a 4V to 60V, 200kHz fixed-frequency controller.

How much input quiescent current does the 12V, 75W converter draw at no load?

It can maintain a no-load output voltage with only 0.1mA of input supply quiescent current.

What efficiency does the example converter achieve?

It provides full-load efficiencies above 95%, with peak conversion efficiencies as high as 96%.

How are low current standby requirements met?

Low current standby requirements are met using Burst Mode operation.