This document describes the technical specifications and main components of Drivecon Inc.'s Traverse Inverter rev 6.0 with software D2S2V051. It also explains the control modes and control methods.
The DriveCon XS Series Service Manual provides detailed information for the installation, commissioning, and safe operation of the XS inverter. It includes technical data, wiring diagrams, component descriptions, and parameter adjustment procedures.
The manual also contains troubleshooting tables, fault code explanations, and service guidelines to help technicians diagnose and repair the inverter. Safety cautions and EMC compliance notes are highlighted throughout the document.
| Power class | 4005, 4010, 4013, 4018, 4024, 4032, 4042, 4048 |
|---|---|
| Supply voltage | 380‑500 VAC |
| Supply frequency | 50‑60 Hz ±5 % |
| Output current (In) | 5.0 A |
| Maximum current (1 min) | 7.6 A |
| Braking torque | 150 % of motor torque |
| Overload protection threshold | 280 % of RMS rated current |
| Undervoltage detection | below 333 V |
| Overvoltage detection | above 911 V |
| Operating temperature range | -10 °C to +50 °C |