This user manual covers the Povos PY-L622-X(C) drinking water machine. It lists component names, control panel keys, precautions, functions, use steps, fault protection, fault checking, cleaning and maintenance, installation diagram, technical parameters, and warranty information.
The control panel section explains heating, cooling, disinfection, and setting operations, including hot and cold water temperature settings, current time, and energy-saving mode. The manual also describes startup steps, normal operating conditions, fault codes E1, E2, and E3, and safety precautions such as grounding, placement clearance, and not using the power plug as a switch. This manual is written in Chinese.
| Bottle compatibility | 3–5 gallon water bottles |
|---|---|
| Ozone cabinet capacity | 20 L |
| Disinfection shelf maximum load | 4 kg |
| Ozone generator effective working life | Over 20,000 hours |
| Hot water temperature setting range | 35°C–95°C |
| Cold water temperature setting range | 5°C–25°C |
| Recommended wall clearance | At least 20 cm |
Remove the bottle cap label, insert the bottle vertically into the smart seat, and press the hot-water key until water flows. Then plug in the power and close the power switch.
Pressing the Disinfection key starts disinfection, and the machine stops it automatically after 30 minutes. Holding the key for 1 second stops disinfection.
E3 indicates a sensor fault; the corresponding heating or cooling end stops working and the buzzer sounds ten times.
Press the hot-water key until water flows from the tap before plugging in power and closing the heating switch, to avoid dry heating. The machine must use a reliably grounded three-core socket and leakage protection switch.