Scanwill MP-Series Hydraulic Pressure Intensifiers Data Sheet

This document is the Scanwill MP series hydraulic pressure intensifier instruction manual, which introduces the features and usage methods of the product, suitable for machine tools, static and impulse testing equipment, hydraulic power packs, stone crushing machines, underwater ROVs, construction tools, pressure die casting machines, quick die changing equipment and other scenarios.


Scanwill MP-Series Hydraulic Pressure Intensifiers Data Sheet - cover page
Brand
Scanwill
Category
Industrial Supply
Document type
Datasheet
Language
English
Pages
12
File format
PDF
File size
2.9 MB
Published
19 March, 2012
Updated
30 September, 2023
MD5 checksum
31CA5182BF16C4C7B3CE59C0296A7020

About this manual

The MP‑Series of hydraulic pressure intensifiers from Scanwill are designed for a wide range of industrial applications, including hydraulic workholding on machine tools, power packs, demolition tools and high‑pressure die‑casting equipment. Each model integrates high‑pressure valves and an optional pilot‑operated check valve (POV) to safely relieve pressure back to tank.

The document provides general material data, temperature limits, compatible fluids and filtration requirements, as well as detailed flow‑and‑pressure tables for each model (MP‑T, MP‑C, MP‑F, MP‑M, MP‑2000). Ordering codes and intensification ratio options are also listed, enabling easy selection for specific system needs.

What's inside

  • Applications
  • General Data
  • MP‑T Pressure Intensifier
  • MP‑C Pressure Intensifier
  • MP‑F Pressure Intensifier
  • MP‑M Pressure Intensifier
  • MP‑2000 Pressure Intensifier
  • Flow & Pressure Tables
  • Ordering Codes
  • Application Examples

Specifications

Body materialCast iron or steel
Surface coatingZinc‑Chrome silver blue finish
Operating temperature range-40 °C to +120 °C
Compatible fluidsRecognised hydraulic fluids and water glycol only
Filtration requirement10 µm nominal, max 19/16 per ISO 4406
MP‑T maximum pressure800 bar (11 600 psi)
MP‑C maximum pressure500 bar (7 000 psi)
MP‑F maximum pressure700 bar (10 150 psi)
MP‑2000 maximum pressure2 000 bar (29 000 psi)
MP‑M maximum pressure800 bar (11 600 psi)

Frequently asked questions

What is the maximum pressure rating of the MP‑T pressure intensifier?

The MP‑T model is rated up to 800 bar (11 600 psi).

Which fluids can be used with Scanwill MP‑Series intensifiers?

Only recognised hydraulic fluids and water‑glycol mixtures are approved; other fluids require factory consultation.

How is the high‑pressure side relieved in the MP‑Series?

A pilot‑operated check valve (POV) integrated in the intensifier can be opened to vent pressure back to the tank.