This is a fan-type refrigerator with environmental antibacterial function.
This manual explains how to safely install and operate the SR-586Q environmental‑protection antibacterial refrigerator. It covers grounding requirements, proper placement, ventilation clearances, and precautions against electrical hazards and misuse of the appliance.
The document also describes the deodorization system, lists the main components and their functions, provides troubleshooting advice, and includes a full set of technical specifications such as power consumption, capacity, and refrigerant details. This manual is written in Chinese.
| Rated Voltage (V) | 110 |
|---|---|
| Rated Frequency (Hz) | 60 |
| Motor Power (W) | 165 |
| Heater Power (W) | 140 |
| Total Capacity (L) | 580 |
| Freezer/Fridge Capacity (L) | 153 |
| Monthly Energy Consumption (kW·h) | 72 |
| Energy Efficiency (L/kWh·month) | 9.71 |
| Refrigerant | R-134a |
| Refrigerant Charge (g) | 145 |
| Product Weight (kg) | 95 |
Connect the grounding wire to the dedicated grounding point on the back left side of the unit, and do not connect it to water pipes, telephone lines, or lightning rods.
Do not place high‑temperature liquids, alcohol, gasoline, or other flammable substances in the freezer to avoid fire or explosion.
Maintain at least 10 cm of space behind the unit and above it for proper ventilation.
Use a dedicated outlet rated at 110 V and 10 A or higher; using a 220 V outlet may cause the compressor to overheat.