This Quick Installation Guide provides information on how to install and configure a VertX V2000 reader interface/access controller.
This guide introduces the HID VertX V2000 (CS) access controller, a device designed for alarm dealers to connect directly to central stations and control two sets of door devices. It includes an introduction, parts list, product and cable specifications, and an overview of the installation process.
The document walks through preparations, hardware mounting, wiring, network and TCP/IP configuration, firewall settings, and final testing with the central station. It also supplies a pre‑installation checklist, FCC compliance information, and contact details for HID support.
| Power Supply Voltage | 12‑16VDC |
|---|---|
| Maximum Current at 12VDC | 1 Amp |
| Average Operating Current | 625 mA (with two iCLASS Readers) |
| Operating Temperature Range | 32°‑122°F (0°‑50°C) |
| Humidity Range | 5%‑95% non‑condensing |
| Input Cable Length | 500 ft (150 m) 2‑conductor shielded |
| Ethernet Cable Length | 328 ft (100 m) Cat5/5E/6 |
The V2000 operates from a 12‑16 VDC power supply.
It is designed to control two sets of door devices, such as two doors or two readers.
Mount the V2000 using the four mounting screws provided in a secure area with room for airflow.
Connect the V2000 to the network using a standard Cat5 cable to the RJ‑45 connector.