Yaohua XK3190-C602 Weight Display Controller Installation and Maintenance Manual

XK3190-C602 weighing display controller user manual, which introduces the installation, wiring, calibration, parameter setting and operation of the product.


Yaohua XK3190-C602 Weight Display Controller Installation and Maintenance Manual - cover page
Brand
XK3190-C602
Category
Other
Document type
Service Manual
Language
Chinese
Pages
98
File format
PDF
File size
729 KB
Published
12 March, 2012
Updated
30 September, 2023
MD5 checksum
22DB8FDEEC8F55C4D1CEE3366262F5E7

About this manual

The manual provides complete instructions for installing, wiring, calibrating and operating the XK3190-C602 weight display controller. It includes detailed diagrams of the front and rear panels, main board, power board, and connection methods for sensors and external devices.

Additional sections cover parameter settings, batch weighing and sorting scale functions, error handling, communication interfaces (including MODBUS RTU), and optional relay box usage. Safety guidelines and technical specifications are also included. This manual is written in Chinese.

What's inside

  • Overview
  • Main Parameters
  • Installation and Wiring
  • Calibration
  • General Parameter Settings and Operation
  • Batch Weighing Operation
  • Sorting Scale Operation
  • Appendices

Specifications

Accuracy class3级
Maximum division (n)3000
Input signal range-15 mV ~ 15 mV
Sensor excitationDC 5 V / 100 mA
Main display6‑digit LED, 0.56 in height
Communication protocolMODBUS (RTU)
Power consumption10 VA
Dimensions (housing)150 × 75 × 105 mm
Weight0.9 kg

Frequently asked questions

How is the controller calibrated?

Calibration is performed according to the method described in Chapter 4, which includes the calibration procedure and data check/modification steps.

What interface is used for a large‑screen display?

The large‑screen display connects via a serial output with an optically isolated 20 mA current‑loop signal.

How many relay outputs are available?

The optional relay box provides eight relay contacts, each rated 220 V AC / 28 V DC at 0.5 A.

Download PDF (729 KB)

More XK3190-C602 Manuals


View all XK3190-C602 manuals →